Everyone is entitled to their own opinion, but not their own facts.

Daniel Patrick Moynihan

Contrary to the assertions of Swinnen et al. [1], Frier [2] and Amiel et al. [3], the American Diabetes Association (ADA) Workgroup on Hypoglycemia [4] defined hypoglycaemia in diabetes as ‘all episodes of an abnormally low plasma glucose concentration that expose the individual to potential harm’. It is not possible to state a single plasma glucose concentration that defines hypoglycaemia because the glycaemic thresholds for responses to falling glucose levels, including those for symptoms, are dynamic. The ADA Workgroup recommended that people with diabetes (implicitly those with insulin secretagogue- or insulin-treated diabetes) should become concerned about the possibility of developing hypoglycaemia at a self-monitored plasma glucose concentration of ≤3.9 mmol/l (70 mg/dl) [4]. Given the limited accuracy of monitoring devices [5], this conservative lower limit for individuals with diabetes approximates the lower limit of the postabsorptive plasma glucose concentration range (approximately 3.9–6.1 mmol/l [70–110 mg/dl] [6]) and the glycaemic threshold for activation of glucose counter-regulatory systems (approximately 3.6–3.9 mmol/l [65–70 mg/dl] [69]), and is low enough to cause reduced glucose counter-regulatory responses to subsequent hypoglycaemia [10] in non-diabetic individuals. It is higher than the glucose levels required to produce symptoms in non-diabetic individuals (approximately 2.8–3.1 mmol/l [50–55 mg/dl] [69]) and substantially higher than those that do so in people with well-controlled diabetes [11], although individuals with poorly controlled diabetes sometimes have symptoms at higher glucose levels [11, 12]. Thus, the recommended glucose alert level of ≤3.9 mmol/l (70 mg/dl) is data-driven, generally gives the patient time to take action to prevent a clinical hypoglycaemic episode, and provides some margin for the limited accuracy of glucose monitoring devices at low plasma glucose concentrations [5]. The ADA Workgroup-recommended alert value does not, of course, mean that people with diabetes should always self-treat at an estimated plasma glucose concentration of ≤3.9 mmol/l (70 mg/dl). Rather, it suggests that they should consider actions ranging from repeating the measurement in the short term, through behavioural changes such as avoiding exercise or driving, to carbohydrate ingestion and adjustments of the treatment regimen.

The data reported by Swinnen et al. [1] nicely document that a higher plasma glucose cut-off value increases the percentage of affected patients and increases the proportion of patients who are asymptomatic; but those are predictable findings. Their data also indicate that a higher cut-off value identifies a higher percentage of patients who suffer severe hypoglycaemia, i.e. it increases sensitivity, albeit at the expense of specificity. This is in line with the evidence of Cox et al. [13] that increasingly frequent lower self-monitored glucose levels identify an increasing risk of imminent severe hypoglycaemia in people with diabetes.

Swinnen et al. [1], Frier [2] and Amiel et al. [3] opine that a lower plasma glucose concentration alert value would be preferable. Collectively, they raise four points. First, plasma glucose concentrations ≤3.9 mmol/l (70 mg/dl) sometimes occur in non-diabetic individuals [1, 3]. This is true, particularly in women and children, albeit generally during prolonged fasting. However, its relevance to people with diabetes, in whom lower glucose levels predict subsequent severe hypoglycaemia [13], is questionable. Second, use of a glucose cut-off value of ≤3.9 mmol/l (70 mg/dl) would overestimate the frequency of clinically important hypoglycaemia [1, 3] or inflate the frequency of clinically meaningless biochemical hypoglycaemia [2]. This criticism is wide of the mark. The issue is not to estimate the frequency of clinically important hypoglycaemia. It is to prevent clinically important hypoglycaemia. A related point is that the guidance given by the Committee for Proprietary Medicinal Products of the European Agency for the Evaluation of Medicinal Products (EMEA/CPMP) [14] on the clinical investigation of medicinal products in the treatment of diabetes, cited by Amiel et al. [3], suggests that the selected glucose level needs to be lower than in clinical practice because a high level of specificity is needed to make claims. But, the issue under discussion is clinical practice, not claims. Furthermore, the guidance includes the erroneous statement that ‘in type 2 diabetes, episodes of hypoglycaemia with severe CNS dysfunction are rare’ [14]. In fact, most episodes of iatrogenic hypoglycaemia, including severe hypoglycaemia, occur in people with type 2 diabetes [15]. Third, the clinical significance of plasma glucose levels of 3.5–4.0 mmol/l (63–72 mg/dl) is probably minor [1], and many clinicians would not consider these to represent significant hypoglycaemia [3]. This ignores the evidence that antecedent plasma glucose concentrations of 3.9 mmol/l (70 mg/dl) reduce the glucose counter-regulatory (including sympathoadrenal) responses to subsequent hypoglycaemia [10], and these diminished responses are a key feature of the pathogenesis of iatrogenic hypoglycaemia in diabetes [15]. Fourth, strict avoidance of such levels is likely to have an adverse effect on average glycaemia [1]. This is entirely speculative.

Frier raises additional issues [2]. His points about the technical aspects of glucose measurements are true, but, in my view, clinically irrelevant given the limited accuracy of devices for self-monitoring blood glucose—generally calibrated to provide estimates of plasma glucose concentrations—at low glucose levels. For example, in one study of a monitor judged by the authors to provide a high degree of accuracy, at glucose levels ≤3.9 mmol/l (70 mg/dl), monitor values were within 10% of the reference blood glucose concentration only 55% of the time and within 15% of the reference value only 70% of the time [5]. With respect to his criticisms of the hyperinsulinaemic–euglycaemic and –hypoglycaemic clamp techniques, intra-individual differences of approximately 0.2 mmol/l (4 mg/dl) [16] hardly represent striking discrepancies; indeed, the authors concluded that the method gave reproducible results [16]. Notably, in his thorough analysis of the methods prior to 1993, Heine [17] specifically endorsed the method used to calculate the glycaemic thresholds for glucose counter-regulatory and symptomatic responses to hypoglycaemia in two of the three studies [7, 8] that generated the glycaemic thresholds mentioned earlier [6]. He also made the point that since ‘real life’ is often replete with uncontrollable confounding factors, its simulation should not be the prime consideration when performing scientific studies [17].

Swinnen et al. [1] advocate a plasma glucose concentration cut-off value lower than 3.9 mmol/l (70 mg/dl), but do not suggest a specific alternative. With no data-driven rationale whatsoever, Frier [2] suggests a cut-off value of 3.5 mmol/l (63 mg/dl), a difference of 0.4 mmol/l (7 mg/dl) from the ADA Workgroup-recommended alert value. Amiel et al. [3] also suggest a value of 3.5 mmol/l (63 mg/dl). Notably, however, they basically endorse the ADA Workgroup alert value, or an even higher value, in that they recommend a therapeutic plasma glucose concentration lower limit of 4.0–4.5 mmol/l (72–81 mg/dl). Thus, it seems there is actually rather little disagreement on this ostensibly contentious issue.